| Öğe açıklaması | Control unit SCF3000 CSA 6A / type designation SCF3000 6A housing design protection class IP54 protection class mains voltage 99V - 264V, 50/60HZ mains type TN system max. permissible input current 2A recommended backup fuse 6A characteristic b or c inrush current 9A, 20MS 16A, RCD (residual current device) type b (all-current sensitive) output voltage 0 ... 205 V across the entire mains voltage range maximum load current 6 A minimum load current 100MA output frequency 35HZ to 140HZ factory setting enable input 24VDC (10-24V) or potential-free contact with internal 24V start-up time: 0 ... 60 sec., factory setting 1.0S deceleration time: 0 ... 60 sec., factory setting 0.1S external analog setpoint 0 ... 10V DC, 0(4) ... 20MA sensor input 1 sensor input, for PNP sensor sensor supply 24V DC, max. 100 MA sensor delay t-on 0 ... 60 sec. Factory setting 5.0S sensor delay t-off 0 ... 60 sec. F |