159060

Détails

Réf. fabricant159060
Réf. EindustN/A
FabricantStahl
Désignation de l'articleSAFETY BARRIER
Description de l'articleSafety barrier (zener barrier), installation in zone 2, 2 channels, electronic current limitation, max. voltage uo: 16, 8 V, max. current IO: 50 MA, max. power po: 840 MW, max. permissible external capacity CO for iib: 1 µf, max. permissible external capacity CO for iic: 0, 16 µf, max. permissible external inductance lo for iib: 2, 5 MH, max. permissible external inductance lo for iic: 0, 86 MH, power supply: Regulated, 12 V DC, maximum output current: 40 MA, potential: Positiv, especially suitable for: I.s. Power supply, solenoids
Groupe d'articlesSecurite
Quantité minimale de commande1

Documents

Fiche techniqueTélécharger

Spécifications

Fin de vie2099-12-31
Division d’articleN/A
Sous-division d’articleN/A
Pays d’origineN/A

Classifications

HSCODEN/A

Commander ce produit

N/A

Devis requis

1