| N.º de pieza del fabricante | 363G97 |
| N.º de pieza de Eindust | N/A |
| Fabricante | Elobau |
| Nombre del artículo | INPUT EXPANSION INTERFACE 363G97 |
| Descripción del artículo | Input expansion interface 363G97 / INTELLIGENT INTERFACE 363G97 SENSOR INPUT 1: NO/NO sensor input 2: NO/NO sensor input 3: NO/NO sensor input 4: NO/NO simultaneity monitoring of sensor contacts: 3S outputs 1 + 2: Connection to a safety relais number of control outputs: 1 common ( for 4 sensor inputs) max. switching current each control output: XXMA max. switching voltagecontrol output: 24VDC +/-10% operating voltage: 24VDC +/-10% max. current consumption (without control outputs): 50MA protection class device: IP 00 connection: Spring-clamp terminals PL (EN ISO 13849-1): D SIL (IEC 61508): 2 SILCL (IEC 62061): 2 category (EN ISO 13849-1): 3 device lifetime: 20 years operating temperature: 0°C...+55°C |
| Grupo de artículo | Automation & Control |
| Cantidad mínima de pedido | 1 |
Documentos
| Hoja de datos técnica | Descargar |
Especificaciones
| Fin de vida | 2099-12-31 |
| División de artículo | N/A |
| Subdivisión de artículo | N/A |
| País de origen | N/A |
Clasificaciones
| HSCODE | N/A |
Ordenar este producto
N/A
Se requiere cotización