| Descripción del artículo | Safety barrier (zener barrier), installation in zone 2, 2 channels, max. voltage uo: 9, 3 V, max. current IO: 20 MA, max. power po: 50 MW, max. permissible external capacity CO for iib: 29 µf, max. permissible external capacity CO for iic: 3, 9 µf, max. permissible external inductance lo for iib: 330 MH, max. permissible external inductance lo for iic: 90 MH, power supply: Regulated, 6 V DC, maximum output current: 11 MA, potential: Channel 1 positiv, channel 2 NEGATIV, especially suitable for: Strain gauge for signal/sense |