| Item Description | B maxx 5300 single axis units / BM5374-F / BMAXX BM5374-F water-cooled with water cooler outside the control cabinet input rated power: 95 KW input rated current: 150 A DC link voltage: 60-760 V DC link capacitance (internal): 2050 µf output rated current at 2 KHZ: 180 A output rated current at 4 KHZ: 150 A output rated current at 8 KHZ: 105 A output rated current at 16 KHZ: 75 A power loss with regard to power supply: 1120 W power loss with regard to control voltage supply: 30 W transport temperature range: -25°C ... +70°C transport climate class (k) (EN 60721-3-2): 2K3 storage temperature range: -25°C ... 55°C storage climate class (EN 60721-3-1): 1K4 operating temperature range: 5°C ... 55°C operating climate class (EN 60721-3-3): 3K3 installation height up to 4000 M above sea level protection class: IP 00 permissible degree of pollution 2 |