31003533

Details

Hersteller-Teilenummer31003533
Eindust-TeilenummerN/A
HerstellerRNA
ArtikelbezeichnungCONTROL UNIT ESR3000 CE+CSA 12A
ArtikelbeschreibungControl unit ESR3000 ce+csa 12A / MAINS VOLTAGE: 240 V +/- 10%, 50/60 HZ 110 V +/- 10%, 50/60 HZ output voltage: 0 ... 205 VEFF / 240 VAC; 0 ... 95VEFF / 110VAC MAXIMUM LOAD CURRENT: 12 AEFF internal fuse: 2X 10A TT output frequency 35 to 140 hertz recommended backup fuse 16A slow-blow, circuit breaker tripping characteristic d input enable: 24V DC (10-24VDC) or potential-free contact with internal 24VDC soft start time: 0 ... 60 sec. Soft stop time: 0 ... 60 sec. External setpoint: 0 ... 10V DC, 0(4) ... 20MA sensor input: 1 sensor input, for PNP sensor sensor supply: 24V DC, max. 100 MA sensor delay on: 0 ... 60 sec. Separately adjustable sensor delay off: 0 ... 60 sec. Separately adjustable status output: Relay, 1 potential-free changeover contact (max. 1A, 250VAC/60VDC) valve output 24VDC, 50MA, short-circuit proof (PNP) -control mode with swing range sensor: Yes ambient temperature:
ArtikelgruppeMotion & Power Transmission
Mindestbestellmenge1

Dokumente

Technisches DatenblattHerunterladen

Spezifikationen

Lebenszyklusende (End of Life)2099-12-31
ArtikelsparteN/A
ArtikeluntergruppeN/A
HerkunftslandN/A

Klassifizierungen

HSCODEN/A

Dieses Produkt bestellen

N/A

Angebot erforderlich

1